How to Choose a Gas Mask: Filter Cartridges by Toxin
A gas mask's protection is not in the facepiece — it is in the filter cartridge. The facepiece body is only the carrying structure; worn alone it gives no protection at all. Choose the wrong cartridge type and toxic gas passes straight through the mask and into the lungs. In spraying, chemical, pickling, refrigeration and laboratory work with toxic gases and vapours, the first step in choosing a gas mask is always the same: find out what toxins are present, then choose the matching cartridge.
Know the Standard First: GB 2890-2022 Is the Current Version
The current mandatory national standard for gas masks is GB 2890-2022, Respiratory Protection — Self-Priming Filter-Type Gas Masks, issued 29 December 2022 and in force from 1 January 2024, replacing GB 2890-2009. The official name for filter cartridges in the standard is "filter element", divided into three main classes by what they protect against: ordinary filter elements, multi-function filter elements and combined filter elements.
The scope must be stated first: GB 2890-2022 does not apply to gas masks for oxygen-deficient environments, underwater work, escape, or firefighting hot zones. In an oxygen-deficient environment below 19.5% oxygen, or where toxic gas reaches immediately dangerous to life or health (IDLH) concentrations, a filtering gas mask cannot be used at all — supplied-air respiratory protection is required. A half facepiece only suits low-concentration environments — the exact concentration limit is in the product instructions.
Filter Cartridge Types and Their Toxins
Ordinary filter elements are divided by what they protect against, each with its own colour code — they must not be mixed:
- Type A (brown): protects against organic gases or vapours with a boiling point above 65 °C, such as benzene, toluene, carbon tetrachloride, nitrobenzene and cyclohexane. Spraying, coating, printing and gluing work usually uses Type A.
- Type AX (brown): protects against low-boiling-point organic vapours with a boiling point of 65 °C or below. Types A and AX cannot replace each other.
- Type B (grey): protects against inorganic gases or vapours, such as cyanogen chloride, hydrogen cyanide and chlorine.
- Type E (yellow): protects against sulfur dioxide and other acid gases or vapours. Acid gases from chemical, metallurgical and pickling work are mainly handled by Type E.
- Type K (green): protects against ammonia and its organic derivatives. Fertiliser, refrigeration and pharmaceutical settings with ammonia need Type K.
- Special filter elements: Type CO (white) protects against carbon monoxide, Type Hg (red) against mercury vapour, and Type H2S (blue) against hydrogen sulfide.
A multi-function filter element covers Types A, B, E and K at once, marked ABEK, with colour bands in brown, grey, yellow and green in sequence, suited to laboratories and chemical workshops with complex gas mixtures. A combined filter element filters particles as well as gases, suited to scenes with both toxic gas and dust.
Protection Capacity: Classes 1, 2 and 3
The same type of filter element is also graded by protection capacity into Classes 1, 2 and 3, marked as the type plus a number — for example A1, A2 and A3. The higher the number, the longer the minimum protection time under standard laboratory conditions: for Type A, the minimum protection time is at least 60 minutes for Classes A1 and A2, and at least 105 minutes for Class A3.
Note that protection time is a test indicator under ideal laboratory conditions, not how long a cartridge lasts on site. On-site gas concentration, temperature, humidity and work intensity all affect the actual protection time — the higher the concentration, the faster the cartridge saturates. When selecting, combine the actual on-site concentration and working time, and leave enough margin.
Four Steps to Select
- Step 1: confirm the toxin. Read the chemical safety data sheet (SDS) to confirm what toxic gases or vapours are present and roughly at what concentration. When the toxin or concentration is unknown, do not select by experience — run occupational hygiene tests first.
- Step 2: choose the cartridge type. Match the toxin type against the table above; for mixed toxins, choose a multi-function or combined filter element.
- Step 3: choose the facepiece. A half facepiece protects the mouth and nose only, suited to scenes where the toxic gas does not irritate the eyes; a full facepiece protects the mouth, nose and eyes, suited to scenes where the gas irritates the eyes or the concentration is higher. The facepiece must pass a fit test — it must match the face shape and not leak.
- Step 4: confirm the conditions of use. Oxygen must be at least 19.5%, and the toxic gas concentration within the applicable range; the facepiece body, filter cartridge and filter cotton must be used together, with matching interfaces — filter cartridges of different brands and series are not necessarily interchangeable.
Frequently Asked Questions
Can a gas mask stop dust?
A gas mask fitted only with a gas filter element cannot stop dust. Where both toxic gas and dust are present, choose a combined filter element, or fit filter cotton outside the gas filter element.
Can a Type A cartridge protect against ammonia?
No. Ammonia needs a Type K filter element. Type A protects against organic gases, Type K against ammonia and its derivatives — the adsorbent formulations differ, so they cannot replace each other.
How often should a filter cartridge be changed?
There is no fixed schedule — it depends on the toxin type, concentration and wearing time. Change it at once when you smell an odour, feel irritation, or breathing resistance rises noticeably. For how to judge the right time, see How Often Should Gas Mask Filter Cartridges Be Replaced?
Can a gas mask be used in an oxygen-deficient environment?
No. A filtering gas mask can only filter toxic gas — it cannot supply oxygen. In an environment below 19.5% oxygen, supplied-air respiratory protection must be used.