How to Wear a Respirator: Fit Check and Seal Test
A respirator rated at 95% filtration efficiency can protect far below its rated value if it is not worn tightly. Air enters straight through gaps at the edges of the mask, and no matter how good the filter layer is, it is wasted. This guide explains the correct wearing steps and seal-check methods for protective respirators.
First, the Standard: KN95 vs KN90
The current standard for self-priming filtering particulate respirators is GB 2626-2019, Respiratory Protection — Self-Priming Filtering Particulate Respirators, published 31 December 2019 and in force from 1 July 2020. The standard divides filter elements into KN and KP classes by filtration performance: the KN class is only for non-oily particles, with three grades — KN90 (filtration efficiency of at least 90%), KN95 (at least 95%) and KN100 (at least 99.97%); the KP class is for oily and non-oily particles, also in three grades, KP90, KP95 and KP100.
Choose by the working environment: KN for non-oily particles only, such as dust; KP where oily particles such as oil smoke or oil mist are present. Choose the grade by the concentration of dust or particles — the higher the concentration, the higher the grade.
Four Steps to Wear It Correctly
1. Inspect the respirator: confirm it is within its validity period, its appearance is intact with no damage or contamination, the headbands or ear loops have normal elasticity, and the nose clip is intact. 2. Cover nose, mouth and chin: the respirator should cover the nose, mouth and chin, with the nose clip at the top and the lower edge wrapping the chin, leaving no gap. 3. Fix the headbands or ear loops: for a headband style, first fix the upper band over the top of the head, then the lower band behind the neck, adjusting to a comfortable tightness; for an ear-loop style, hook each loop behind the ear. 4. Shape the nose clip: using both index fingers, press the nose clip slowly and in sections from the centre of the nose bridge out to both sides, so it fully follows the shape of the nose bridge. Do not pinch the nose clip with one hand — that easily leaves a gap.
During the whole process, touch only the headbands or ear loops with your fingers, and avoid touching the inside of the respirator.
Seal Check: Do It Every Time You Wear One
After putting on a respirator, you must do a seal check to confirm a good seal before entering the work area. Two self-test methods:
- Negative-pressure inhalation test: cover the respirator completely with both palms and inhale slowly and deeply. If it passes, the respirator collapses slightly inward and hugs the face, with no air drawn in at the edges and no leaking sound.
- Positive-pressure exhalation test: cover the edges of the respirator with both hands and exhale steadily and firmly. With a good seal, the respirator bulges slightly, and no air escapes at the nose bridge, cheeks or chin.
If the check finds a leak, readjust the respirator position, headband tightness and nose clip, then check again. If it still leaks after repeated adjustment, change the respirator or try another model or size. When the face shape does not match the respirator, even the most expensive mask will not seal well.
After long wear, a respirator that is damp, deformed or has slack ear loops loses its seal, so recheck regularly and replace it promptly when it is deformed or damp.
Common Mistakes: Wearing It Like This Is Like Not Wearing One
- Not pressing the nose clip: both sides of the nose bridge are the most common leak points — if the nose clip does not fit, it is like leaving two air inlets open.
- Covering the mouth but not the nose: the nose is the main channel for particles into the respiratory tract — not covering it is the same as not wearing a mask.
- Wearing only one headband: both straps of a headband respirator must be worn — with only one, it cannot be held firmly and the seal is poor.
- Wearing the respirator inside out: the nose clip goes on top and the dark or waterproof side faces out — worn the other way, both seal and filtration suffer.
- Wearing a respirator over a big beard: facial hair breaks the seal between the respirator and the face and causes leaks. Jobs that require a protective respirator should keep the face clean.
- Wearing one respirator for days: once damp, deformed or contaminated, a respirator's filtration efficiency and seal both drop — replace it in time, following the instructions and the working environment.
Frequently Asked Questions
Must I do a seal check every time?
Yes. Do a seal check every time after putting on a protective respirator, and confirm a good seal before entering the work area. It is part of the wearing process, not an optional extra step.
Must I do both the positive- and negative-pressure checks?
Each method checks something different, so doing both is recommended. The negative-pressure check shows whether air leaks in when you inhale, and the positive-pressure check shows whether air leaks out when you exhale — only when both pass is the seal good.
How can glasses wearers avoid leaks and fogging?
The key is shaping the nose clip. Once the nose clip fits the nose bridge, exhaled air cannot leak out from the top, and glasses are less likely to fog. You can also choose a respirator or goggles with an anti-fog design.
How long can a respirator be worn before replacing it?
Follow the product instructions and the working environment. Replace it at once when it is damp, deformed, damaged or when breathing resistance rises noticeably; after contact with contaminants, replace it as required and do not use it beyond its life.