Category: Protective Supplies

Laboratory PPE Guide: Configuration by Risk Level

Biological samples, chemical reagents, sharps and aerosols may all be present in a laboratory at the same time. Too little PPE leaves lab staff directly exposed to risk; the wrong PPE means gloves still get corroded and coveralls still get infected. This guide explains how to configure laboratory PPE by risk level.

First, Set the Level: PPE Follows the Biosafety Level

Laboratories that handle biological agents follow GB 19489-2008, General Requirements for Laboratory Biosafety. The standard divides laboratory biosafety protection into four levels — level 1, level 2, level 3 and level 4, with level 1 the lowest and level 4 the highest:

  • BSL-1: work with micro-organisms that do not normally cause human or animal disease.
  • BSL-2: work with micro-organisms that can cause human or animal disease, but with limited harm and limited risk of spread, rarely causing serious disease after infection, and with effective treatment and prevention.
  • BSL-3: work with micro-organisms that can cause serious disease and spread relatively easily between people, or between animals and people.
  • BSL-4: work with micro-organisms that can cause very serious disease, and micro-organisms not yet found in China or declared eradicated.

PPE configuration starts from the laboratory's protection level and risk assessment results — the basic configuration of a BSL-1 lab and a BSL-3 lab is completely different and cannot be copied across. The standard states that when risk control measures are taken, eliminating the hazard should be considered first, then reducing the risk, and only lastly personal protective equipment. PPE is the last line of defence, not the first.

Basic Configuration: Every Lab Needs These

Whatever the level, every laboratory should be equipped with the following basic PPE:

  • Lab coat or workwear: must be worn on entering the laboratory, and stored separately from personal clothing; a BSL-1 laboratory should have a clothes storage or hanging facility at the entrance, keeping personal clothing separate from workwear.
  • Protective gloves: disposable nitrile or latex gloves, worn when handling samples and reagents; people allergic to latex should choose nitrile gloves. Replace at once when damaged or contaminated, and wash or disinfect hands after removing gloves.
  • Protective glasses or goggles: must be worn for any operation with a risk of liquid splashes — ordinary glasses cannot replace them. For operations with an aerosol or splash risk, choose well-sealed goggles.
  • Masks: choose a disposable medical mask or a KN95 or higher protective mask by risk; operations that may generate aerosols should use a higher grade and include a seal check.
  • Hand-washing facilities: the laboratory should have a wash basin, preferably near the exit, with hand wash or hand disinfectant.

Add by Risk: Chemical, Biological and High-Risk Work

  • Chemical laboratories: for corrosive or irritating reagents, choose chemical-resistant gloves (nitrile gloves suit a wide range — check the product instructions for the exact resistance), goggles, a protective suit or apron, and a face shield where necessary. For highly toxic, radioactive and similar substances, equip the corresponding safety facilities, equipment and PPE under national and local rules.
  • BSL-2 laboratories: operations that may generate aerosols should be carried out in a biological safety cabinet, with medical protective masks and goggles, and protective suits and shoe covers where necessary; the main entrance door should close automatically and have access control.
  • BSL-3 and above: protection requirements rise sharply, involving positive-pressure protective suits, respiratory protection and other specialist equipment. Configuration should be set by biosafety specialists on the basis of a risk assessment, and is outside the scope of this guide.

Buying, Acceptance, Use and Disposal

Buying and acceptance points:

  • Gloves: check the material (nitrile or latex), size and whether they are powdered. Laboratories generally choose powder-free gloves, to avoid powder contaminating samples and instruments.
  • Protective glasses and goggles: check anti-fog performance and fit; lab staff who wear glasses should choose a style that fits over prescription glasses.
  • Protective suits: for chemical laboratories choose suits resistant to chemical penetration, for biological laboratories choose suits meeting the relevant standards, and check size and seam sealing.
  • Masks: check the standard number (GB 2626-2019 or GB 19083-2010) and the filtration level, and check the production date and expiry date.
  • On acceptance, check that the product name, model, specification, quantity and standard number match the purchase contract, and request the test report.

Use and disposal management:

  • Do not reuse disposable PPE. Gloves, masks and protective suits that have touched biological samples should be treated as infectious waste and put in yellow medical waste bags.
  • Reusable glasses and face shields should be cleaned and disinfected after use and stored in a clean, dry place.
  • Lab coats should be washed regularly, separately from personal clothing; contaminated coats should be handled under laboratory rules and must not be worn outside the laboratory.
  • PPE should be stored at fixed points, managed by a named person, with stock and expiry dates checked regularly, and damaged or expired items replaced promptly.

Frequently Asked Questions

Should lab gloves be nitrile or latex?

Each suits different scenes. Nitrile gloves resist chemicals better, do not cause allergies and suit a wide range; latex gloves are more elastic and fit closely, but carry a latex allergy risk. Laboratories generally prefer nitrile gloves, and anyone with a latex allergy history must use nitrile gloves.

Can ordinary glasses be used as protective glasses?

No. Ordinary glasses have no side protection and cannot protect the eyes when liquid splashes. Any operation with a splash risk requires protective glasses or goggles.

Must a BSL-2 laboratory have a biological safety cabinet?

When a BSL-2 laboratory carries out operations that may generate aerosols, they should be done inside a biological safety cabinet. A biological safety cabinet is basic isolation equipment for a laboratory, not PPE, and its configuration and acceptance follow the relevant rules.

How often should lab PPE be replaced?

Disposable items are changed after one use; reusable items are replaced under the product instructions and laboratory rules. Replace gloves at once when damaged, masks when damp or deformed, and protective suits when damaged or contaminated — do not wait until the end of the shift.

WhatsApp 18300232331 Get a Free Quote
Chat Get a Quote