How to Choose Anti-Static Workwear: Electronics & Petrochem
Anti-static workwear is essential in both electronics and petrochemical plants, but the two industries prevent static for different reasons: electronics plants stop static from breaking down components, while petrochemical plants stop static sparks from igniting or exploding. Different purposes mean different selection — taking electronics workwear into a chemical plant, or the reverse, can cause problems.
The Standard and Two Key Indicators
The current national standard for anti-static workwear is GB 12014-2019, Protective Clothing — Anti-Static Clothing, published 31 December 2019 and in force from 1 July 2020, replacing GB 12014-2009 and GB/T 23464-2009. The 2019 edition removed the grading of anti-static workwear and set out the test details and requirements for charge quantity and point-to-point resistance.
Remember the two key indicators: point-to-point resistance should be between 1×10⁵ Ω and 1×10¹¹ Ω, and charge quantity must not exceed 0.6 μC per garment. Resistance that is too low brings a risk of electric shock from conduction, while resistance that is too high cannot carry static away; a charge quantity over the limit shows the garment cannot dissipate static well enough. Check the test report when buying — both figures must be in the report, not just the words "anti-static".
Also read the scope of the standard: GB 12014-2019 applies to anti-static clothing worn where static may cause electric shock, fire or explosion. It does not apply to nonwoven anti-static clothing or to anti-static clothing for protection against mains voltage — disposable nonwoven anti-static garments and voltage-resistant anti-static garments each have their own standards and requirements.
Electronics: Anti-Static and Dust Control
In electronics, anti-static workwear stops electrostatic discharge from breaking down chips and components. The static the human body builds up through movement cannot be seen or felt, but it is enough to destroy precision components. Anti-static workwear is one part of a static protection system, used together with anti-static shoes, wrist straps and flooring — wearing the garment alone while ignoring the other links leaves the protection incomplete.
Electronics workshops also demand cleanliness, so the workwear fabric must not shed fibres or lint, and styles are mostly one-piece suits or two-piece sets with tight cuffs and trouser hems. Anti-static workwear must be washed and stored to cleanroom requirements, never washed or stored together with ordinary workwear.
When buying, focus on whether charge quantity and point-to-point resistance meet the standard, whether the fabric suits a clean environment, and whether the style hampers fine work. Poor-quality products with unevenly distributed conductive fibres have unstable anti-static performance — and are more dangerous, not less.
Petrochemicals: Anti-Static Is the Baseline, Add Flame Retardance
In petrochemicals, anti-static workwear stops static sparks from igniting flammable gases, liquids and dust. Petrol stations, oil depots, chemical plants, paint shops and dusty workshops are all places where static can cause fire or explosion, so anti-static workwear is a hard requirement.
Petrochemical anti-static workwear often also needs flame retardance: the site carries both a static risk and a risk of open flame or sparks, so anti-static alone is not enough — it must also meet GB 8965.1-2020, Protective Clothing — Flame Retardant Clothing. Confirm when buying that the protection functions match the job risk.
Petrochemical workwear must also resist oil stains and chemical splashes, with heavier fabric and higher abrasion resistance, and styles are mostly two-piece for easy donning and doffing.
Use and Washing Rules
The conductive fibres are the key to anti-static performance, and wrong washing or wearing damages them. Wash and maintain the garment as the manufacturer instructs — do not use strong acid or alkaline detergents on your own, do not scrub hard, and do not dry it in strong sun. A garment with damaged or broken conductive fibres loses anti-static performance, so inspect it and replace it in time.
Do not attach insulating items to anti-static workwear, and do not print over large areas with insulating ink or add thick embroidery — these cover and interrupt the conductive fibres. Where a company logo must be printed, confirm the printing method and position with the manufacturer first.
Frequently Asked Questions
Can electronics anti-static workwear be worn in a chemical plant?
Not necessarily. Electronics workwear mainly stops static from damaging components, while chemical plants also need to stop static sparks from igniting or exploding. Some posts also need flame retardance. Check each requirement against the job risk before buying — do not use one type for both.
How can I tell genuine anti-static workwear from fake?
Check three things: whether the marking is complete and the standard is GB 12014-2019; whether the test report shows point-to-point resistance and charge quantity meeting the standard; and whether conductive fibres are evenly distributed in the fabric. Be cautious of a product that only says 'anti-static' with no test report.
Can anti-static workwear be worn with ordinary clothes?
No. Wearing ordinary chemical-fibre underwear inside anti-static workwear, or an ordinary jacket over it, weakens static dissipation. Anti-static workwear must be worn as a complete set to the rules, together with anti-static shoes.
How often should anti-static workwear be tested?
Test it regularly under the company's management rules, and send key posts for regular testing of point-to-point resistance and charge quantity. Stop using and replace any garment that fails a test at once — do not keep wearing it.