Category: Fire Equipment

How to Build a Mini Fire Station: Equipment List

A mini fire station is the volunteer fire team of a fire-safety key unit or a community, with the goal of having "personnel, equipment and fighting capability" — able to deal with a fire in its initial stage without waiting for the fire brigade. Building one takes three things, none of which can be missing: personnel, premises and equipment.

The Basis: Gongxiao [2015] No. 301

The basis for building a mini fire station is Notice Gongxiao [2015] No. 301, issued by the Fire Department of the Ministry of Public Security on 11 November 2015, containing two trial standards: the Construction Standard for Mini Fire Stations in Fire-Safety Key Units (Trial) and the Construction Standard for Community Mini Fire Stations (Trial). Fire-safety key units and communities should both build stations under this standard.

The construction principle is "personnel, equipment and fighting capability", to achieve the goal of effectively dealing with initial fires. A mini fire station is not a decoration — once built it must be able to turn out and fight fires, and fire rescue agencies regularly check the actual fighting capability of stations.

Staffing: At Least 6 People

A mini fire station should have at least 6 people. It should have a station chief, a deputy chief, firefighters, control-room duty officers and other posts; a station equipped with a fire vehicle should also have a driver post. The station chief is generally the unit's fire safety manager, and firefighters are selected from the unit's employees — healthy and responsible.

Staff must receive pre-post training, covering skills for fighting initial fires and basic fire patrol knowledge. Training is not a one-off — drills should be organised regularly, so staff know how to use the station's equipment and the unit's evacuation routes. When staff change, new staff should be trained promptly, so the station never ends up with nobody who can use the equipment.

A duty system must be in place: a mini fire station should have a 24-hour duty system, and control-room duty officers should know alarm and linkage operations. On receiving a fire alarm, duty staff should be able to turn out quickly, deal with the initial fire, guide evacuation, and report the fire to the fire brigade.

Premises and Equipment: Extinguishers Are the Core

A mini fire station should have rooms for personnel on duty and equipment storage, which can be shared with the fire control room, or set up separately where conditions allow. The station should be located for easy turnout and equipment access, with rooms and space meeting the basic needs of daily duty and equipment storage, and an outside telephone line.

Equipment is divided into three categories under the standard:

Fire extinguishing equipment: a number of fire extinguishers, water guns, hoses and similar items, as needed to fight initial fires. Extinguishers are generally portable dry powder extinguishers, in a number set by site area and risk; water guns and hoses must match the hydrant connections; stations with the conditions can also equip fire pumps and fire hose reels.

Communications equipment: an outside telephone line, hand-held walkie-talkies and similar items. In a fire, the station must be able to raise the alarm quickly and communicate internally, and walkie-talkies must be fully charged with a unified channel.

Personal protection and breaking equipment: stations with the conditions can optionally equip fire helmets, firefighting suits, protective boots, breaking tools and similar items. Firefighters entering a fire scene must wear protective equipment — they cannot rush in wearing ordinary clothes.

Community mini fire stations are configured slightly differently: they should be equipped with fire motorcycles and basic fire extinguishing equipment and personal protective equipment such as extinguishers, water guns and hoses, as needed to fight initial fires in the community, and can optionally equip a small fire truck where conditions allow.

Storage Points, Checklist and Daily Management

A mini fire station should set up equipment storage points inside buildings and on refuge floors, and can set them up by zone between buildings where needed. Equipment kept only in the station building is inconvenient to reach from a distant fire point and delays firefighting.

The principles for storage points are: every storage point should have a fire extinguisher, with hoses and water guns added in key areas; storage points should be clearly located and marked, so employees know where they are; and storage-point equipment should be checked regularly and kept in the management ledger together with the station's equipment.

Below is a basic mini fire station configuration checklist organised under Gongxiao [2015] No. 301 — adjust the exact quantities by unit size and site risk:

Fire extinguishing equipment: several portable dry powder fire extinguishers, at least 2 fire hoses, at least 2 straight-stream water guns, 1 fire pump (where conditions allow), and fire hose reels as needed.

Communications equipment: 1 outside telephone line, at least 2 hand-held walkie-talkies.

Personal protection: fire helmets, firefighting suits, protective boots and fire gloves, equipped by firefighter numbers.

Breaking tools: fire axes, shovels, crowbars and similar items, equipped as needed.

Other items: emergency lights, filtering self-rescuers, first aid kits, warning tape and similar items, equipped as needed.

Once a mini fire station is built, it must be managed: equipment ledgers, inspection records, drill records and duty records should all be kept. Fire extinguishers should be checked monthly and repaired or scrapped when due, hoses and water guns checked regularly, and protective equipment cleaned and maintained regularly.

Organise at least one equipment check each month and at least one fire drill each quarter. Drills should be close to real combat, simulating fires in different locations and practising the full process — receiving the alarm, turning out, extinguishing, evacuating and reporting. Problems found in drills should be recorded and corrected, not glossed over.

Frequently Asked Questions

Which units must build a mini fire station?

Fire-safety key units and communities must build one. Fire-safety key units are determined and announced by fire rescue agencies, and include large shopping malls, markets, hotels, hospitals, schools and flammable and explosive sites. Units that are not key units may also build one voluntarily.

What is the difference between a mini fire station and a full-time fire brigade?

A mini fire station is a volunteer fire team — its members are unit employees working part-time, dealing with initial fires. A full-time fire brigade is a professional team with full-time members and fire trucks, and much stronger capability. Large enterprises and chemical parks should build full-time brigades; a mini fire station is enough for ordinary units.

Can an equipment cabinet replace a station building?

An equipment cabinet is one form of equipment storage, suited to units with limited space. But the standard requires rooms for personnel on duty and equipment storage — a cabinet can be shared with the fire control room, but a cabinet alone with no people is not enough. Personnel and a duty system are essential.

Must a mini fire station register with the fire department?

The construction standard does not set a uniform registration procedure, but fire rescue agencies inspect and guide mini fire stations. Follow the local fire rescue agency's requirements, and reporting to the local fire rescue agency after building a station is good practice.