Category: Labor Protection Supplies

What Is the Test Standard for Anti-Static Safety Shoes?

Anti-static safety shoes are tested to GB 21148-2020, Foot Protection — Safety Footwear, and the key measure is electrical resistance: an anti-static shoe must measure between 100 kΩ and 1000 MΩ (10^5–10^9 Ω). Below the lower limit the charge drains too fast; above the upper limit static cannot drain away at all. Anti-static shoes and insulating shoes do opposite jobs — never mix them up.

Test Standards and Limits

  • Product standard: GB 21148-2020, Foot Protection — Safety Footwear, where anti-static performance is an additional functional requirement.
  • General specification: GB 20098-2025, Foot Protection — General Technical Specifications, published on 29 August 2025 and in force from 1 September 2026, is the general framework for foot protection.
  • Test method: GB/T 20991-2024, Foot Protection — Test Methods for Footwear, in force from 1 January 2026, replacing the 2007 edition.
  • Resistance: 100 kΩ–1000 MΩ is the acceptable range. For the test, steel balls are placed inside the shoe and it is set on a metal probe rig, with measurements taken in both dry and wet conditions.

Anti-Static Shoes Are Not Insulating Shoes

  • Anti-static shoes: resistance 100 kΩ–1000 MΩ, draining the body's static charge to the ground in time to stop static build-up from igniting or exploding — for electronics, petrochemical and flammable or explosive premises.
  • Electrical insulating shoes: high-resistance isolation, blocking mains-frequency current from passing through the sole into the body, and required to withstand a specified power-frequency voltage, with resistance at the megaohm level and above.
  • The two do opposite jobs and cannot replace each other: anti-static shoes must never be used as insulating shoes, and insulating shoes cannot serve as anti-static shoes.
  • Note: GB 12011-2009, Foot Protection — Electrical Insulating Shoes, has been withdrawn. Electrical insulating shoes now follow the GB 20098-2025 general specification and the GB/T 20991-2024 test methods — do not buy or accept goods against GB 12011-2009 any more.

How Often to Retest in Use

  • Retest the resistance generally after no more than 200 hours of wear. Outside the 100 kΩ–1000 MΩ range, the shoes can no longer be used as anti-static footwear.
  • Products more than 18 months from their production date should pass the relevant electrical performance checks before use.
  • Use them as a system: anti-static shoes work with anti-static flooring and anti-static workwear — one pair of shoes alone is not a complete anti-static system. Do not wear thick insulating wool socks or insulating insoles with them.
  • On delivery, check the standard number, certificate of conformity and test report, sample-check the resistance, and verify the report number on the national certification and accreditation information platform.

Frequently Asked Questions

What resistance is acceptable for anti-static shoes?

Between 100 kΩ and 1000 MΩ (10^5–10^9 Ω). Below 100 kΩ the charge drains too fast; above 1000 MΩ static cannot drain away. Both fail.

Can anti-static shoes be used as insulating shoes?

No. The two do the opposite: anti-static shoes drain static away, insulating shoes block current. Anti-static shoes must never be used as insulating shoes, and insulating shoes cannot serve as anti-static shoes.

How often should anti-static shoes be retested?

Generally after no more than 200 hours of wear, test the resistance again. If it falls outside the acceptable range, stop using the shoes as anti-static footwear at once.

Can GB 12011-2009 still be used?

No. GB 12011-2009, Foot Protection — Electrical Insulating Shoes, has been withdrawn. Electrical insulating shoes now follow the GB 20098-2025 general specification and the GB/T 20991-2024 test methods — do not write GB 12011-2009 on purchase or acceptance documents any more.