How to Choose Insulated Safety Shoes: Voltage Ratings

Insulated safety shoes are foot protection for electrical work: the insulated sole breaks the path of current through the body via the feet, protecting the wearer from electric shock. Many people buy insulated shoes by looking only at numbers such as "6kV" and "12kV", thinking the number is the voltage they can work on. That is the most common misunderstanding: the figure marked on the shoe is the test voltage, not the working voltage. This guide explains the voltage ratings, scope of use and inspection requirements for insulated safety shoes.

First, the Standard: GB 12011-2009

The national standard for electrical insulating footwear is GB 12011-2009, Foot Protection — Electrical Insulating Footwear, published 13 April 2009 and in force from 1 December 2009. It sets out the classification, styles, technical requirements, test methods, inspection rules and marking of electrical insulating footwear, and applies to electrical insulating footwear used as an auxiliary safety device when working on electrical equipment.

The standard classifies electrical insulating footwear by upper material into electrical insulating leather shoes, cloth-upper rubber shoes, full-rubber boots and full-polymer boots, and by test voltage into different grades: leather shoes at 6 kV, cloth-upper rubber shoes at 5 kV and 15 kV, and full-rubber and full-polymer boots at several grades including 6 kV, 10 kV, 15 kV, 20 kV and 30 kV. The upper or sole should carry the shoe size, standard number, the words "electrical insulating" or the letters "EH", a lightning mark and the withstand voltage value.

Note that electrical insulating footwear is only an auxiliary safety device and cannot guarantee 100% protection against electric shock. For live work, insulated shoes must be used together with insulated gloves, insulated tools and other equipment — never rely on one pair of shoes alone.

Test Voltage Is Not Working Voltage

This is where selection most often goes wrong. The 6 kV, 12 kV and 15 kV marked on a shoe are the test voltages applied during factory inspection and preventive testing — not the voltage the wearer can work on.

The general rule for scope is: electrical insulating footwear with a test voltage of 15 kV or below is for working environments at power frequency up to 1000 V; full-rubber and full-polymer boots with a test voltage of 15 kV or above are for working environments at power frequency above 1000 V. In other words, a pair of electrical insulating leather shoes marked 6 kV is for low-voltage work, not for working on a 6 kV line.

When choosing, first confirm the voltage of the working environment: for low-voltage distribution, electrical equipment maintenance and other work below 1000 V, choose electrical insulating leather shoes or cloth-upper rubber shoes; for high-voltage environments, choose full-rubber or full-polymer boots with a high test voltage. If unsure, consult the supplier or check against the electrical safety work rules.

Impact and Puncture Protection: The Other Side of Insulated Shoes

Many insulated safety shoes also protect against impact and puncture, under GB 21148-2020, Foot Protection — Safety Footwear. The toecap and puncture-resistant insert in such shoes have special requirements: to keep the insulation performance, a non-metallic toecap and non-metallic puncture-resistant insert should be used; if a metallic toecap is used, it must be insulated. When buying, confirm the product meets both GB 12011 and GB 21148, and that the test report covers both insulation and impact/puncture performance.

Also note that the insoles of insulated shoes must not be replaced at will. Some insoles are conductive, and the wrong insole can destroy the insulation of the whole shoe. When an insole needs replacing, use the original manufacturer's insole or one confirmed by the supplier.

Preventive Testing: Every 6 Months

Electrical insulating footwear must be put through preventive testing regularly, on a 6-month cycle. Testing is generally a power-frequency withstand test: insulating boots at 15 kV for 1 minute, with leakage current no more than 7.5 mA; leather shoes and cloth-upper rubber shoes are tested at the voltage for their grade. Any shoe that fails the test is scrapped immediately and must not be worn again.

The service life of electrical insulating footwear is generally 24 months from the production date. After 24 months, each pair must pass an electrical preventive test before it can be used, and each test result is valid for no more than 6 months. In other words, shoes that have sat unworn for a long time must be tested before they are worn — never put them straight on.

For daily use: keep the uppers dry, and keep them away from sharp objects, high temperatures and corrosive substances; replace the shoe at once if the upper or sole is corroded or damaged; and do not let the soles get wet or oily when wearing them, as dampness lowers insulation.

Frequently Asked Questions

Can shoes marked 6kV be used for work on a 6kV line?

No. 6 kV is the test voltage, not the working voltage. Insulated shoes with a test voltage of 15 kV or below are for power-frequency work environments below 1000 V. High-voltage work needs full-rubber or full-polymer boots with a high test voltage.

How often must insulated safety shoes be tested?

The preventive test cycle is 6 months. Service life is generally 24 months; beyond 24 months, each pair must be tested and pass before use, and each test result is valid for no more than 6 months.

Can I change the insoles in insulated shoes?

Not at will. Some insoles are conductive, and the wrong insole can destroy the insulation of the whole shoe. When replacing, use the original manufacturer's insole or one confirmed by the supplier.

Can insulated shoes be worn when wet?

Damp uppers and soles lower insulation, so dry them before wearing. If the upper or sole is corroded or damaged, replace the shoe at once and do not keep wearing it.