Category: Labor Protection Supplies

How to Choose Insulated Gloves: Voltage Classes & Tests

Insulated gloves are the most critical protective item for electrical work — and the easiest to get wrong. Choose a voltage class too low and the glove will break down; buy a pair and never test or inspect it, and the rubber ages and develops pinholes without you knowing — wearing it is the same as wearing nothing. This guide explains the voltage classes, selection method and inspection requirements for insulated gloves under the current standard.

First, the Standard: GB/T 17622-2008 Is the Current Edition

The current national standard for insulated gloves is GB/T 17622-2008, Insulating Gloves for Live Working, identical in adoption to the International Electrotechnical Commission standard IEC 60903. The standard divides insulated gloves into six classes by maximum working voltage — 00, 0, 1, 2, 3 and 4 — each with a different maximum AC and DC working voltage:

  • Class 00: maximum AC 500 V, DC 750 V. For low-voltage distribution and small distribution-box maintenance.
  • Class 0: maximum AC 1000 V, DC 1500 V. For low-voltage line repair and distribution-room work.
  • Class 1: maximum AC 7500 V, DC 11250 V. For live work on 10 kV medium-voltage distribution lines.
  • Class 2: maximum AC 17000 V, DC 25500 V. For 35 kV substation equipment maintenance.
  • Class 3: maximum AC 26500 V, DC 39750 V. For high-voltage transmission line work.
  • Class 4: maximum AC 36000 V, DC 54000 V. For extra-high and ultra-high voltage work.

The hard rule for selection: the glove's maximum working voltage must be higher than the voltage of the workplace. Choose the class that matches the working voltage, or a higher class — never make do with a lower class. A glove's colour has nothing to do with its protection class; read the class marking on the glove.

Factory Verification and Preventive Testing

Insulated gloves are electrically verified before leaving the factory, at different proof voltages by class: class 00 at 2.5 kV, class 0 at 5 kV, class 1 at 10 kV, class 2 at 20 kV, and class 3 at 30 kV. The proof voltage is higher than the maximum working voltage, leaving a safety margin.

After purchase, gloves must also be put through preventive testing regularly. Under DL/T 976-2017, Preventive Test Code for Live Working Tools, Devices and Equipment, the preventive test cycle for insulated gloves is 6 months. Preventive testing is generally an AC withstand test: high-voltage insulated gloves at 8 kV for 1 minute, with leakage current no more than 9 mA; low-voltage insulated gloves at 2.5 kV for 1 minute, with leakage current no more than 2.5 mA. Any glove that fails is scrapped immediately and must not be used again.

Besides regular testing, inspect the glove before every use — appearance and airtightness: check for damage, cracks, holes and ageing or stickiness; roll up the cuff and inflate the glove to check for leaks. If you find any damage or leak, stop using it at once.

Categories and Use With Other PPE

By extra performance, insulated gloves are divided into several categories: A for acid resistance, H for oil resistance, Z for ozone resistance, R for acid, oil and ozone resistance, and C for extreme cold resistance. Choose by the working environment: A or R where acids are handled, H or R where oils are handled, Z or R in outdoor ozone environments, and C in cold environments.

When using insulated gloves, note the following:

  • Wear protective gloves over them. The rubber of an insulated glove is easily cut by sharp objects, so a leather protective glove should be worn over the insulated glove during work to prevent mechanical damage. A protective glove cannot replace an insulated glove — the two work as a pair.
  • Use them with insulated shoes and insulating mats. Hand insulation and foot insulation go together — wearing insulated gloves without insulated shoes leaves the protection incomplete.
  • Before putting on insulated gloves, check your hands for sharp jewellery and whether your nails are too long, to avoid cutting the inside of the glove.

Storage and Management

  • Store away from light, in a dry, ventilated place, avoiding direct sunlight, high temperatures and ozone. Rubber gloves fear light, heat and ozone, and poor storage speeds up ageing.
  • Do not fold or squeeze them in storage. Folds easily develop cracks — store gloves flat or hung up.
  • Keep a register. Number each pair of insulated gloves and record the purchase date, test date and next test date; gloves past their test date must not be used.
  • Gloves past their test date must not be used even if they look fine. A drop in insulation performance cannot be seen from the outside — only a test can verify it.

Frequently Asked Questions

How high a voltage can insulated gloves be used on?

Read the class marking on the glove. Class 00 is for up to 500 V AC, class 0 for 1000 V, class 1 for 7500 V, class 2 for 17000 V, class 3 for 26500 V, and class 4 for 36000 V. The working voltage must be below the glove's maximum working voltage.

How often must insulated gloves be tested?

Under DL/T 976-2017, the preventive test cycle is 6 months. Before every use, also do an appearance and airtightness check, and stop using the glove at once if you find damage or leaks.

Can a glove with a small hole still be used?

No. Any damage, hole or crack makes the insulation fail, with a risk of electric shock. Scrap a damaged glove at once — do not repair it and keep using it.

Can ordinary rubber gloves be used as insulated gloves?

No. Ordinary rubber gloves have not been through electrical performance testing, so their insulation is not guaranteed and they cannot be used for live work. Insulated gloves must meet GB/T 17622-2008 and have a test report and test pass records.