Fire Gloves & Fire Boots: How to Choose Them
Fire suits and helmets get bought as a set, but gloves and boots are often thrown in casually — a common weakness in team equipment. In a fire, hands touch hot door handles and move scorching objects, and feet step on broken glass, nails and standing water. If the protection level for hands and feet is not enough, the whole protective set has two holes in it.
Know the Standards First: GA 7-2004 and GA 6-2004
The current industry standard for fire gloves is GA 7-2004, Fire Gloves, and for firefighter fire protection boots it is GA 6-2004, Firefighter Fire Protection Boots. In 2020, a Ministry of Emergency Management announcement changed the code for fire and rescue industry standards from "GA" to "XF", keeping the sequence number, year and content unchanged — so GA 7-2004 and XF 7-2004, and GA 6-2004 and XF 6-2004, are the same standard under two codes, and either code may be written on a purchase contract.
Like fire helmets, fire gloves and fire boots had compulsory product certification cancelled in 2019 and moved to voluntary product certification, under implementation rule CCCF-CPRZ-27:2019, Fire Product Certification Implementation Rules — Fire Equipment Products: Firefighter Personal Protective Equipment Products. When buying, check the voluntary certification certificate and the type test report — do not judge by the 3C mark alone. Fire helmets follow the same voluntary-certification route since 2019.
Fire Gloves: Four Layers, and Flexibility Must Not Be Lost
A fire glove generally has four layers: the outer layer, the waterproof layer, the heat-insulating layer and the lining. The outer layer uses permanently flame-retardant fibre or leather, and is wear-resistant and flame-retardant; the waterproof layer keeps firefighting water out; the heat-insulating layer blocks heat; and the lining fits the hand and absorbs sweat. When buying gloves, confirm all four layers are present — missing the waterproof or heat-insulating layer greatly weakens protection.
Focus on these points when choosing:
- Heat protection: overall thermal protective performance (TPP value) is the core indicator — the higher the value, the longer the protection time. Take the exact figure from the test report.
- Flexibility and grip: gloves that are too thick or stiff cannot hold a nozzle, open a valve or fasten a button, however good their protection. Test in practice: wearing the gloves, can you grip a nozzle tightly, turn a hydrant valve and fasten a button?
- Cut, tear and puncture resistance: a fire scene has broken glass, sheet metal and nails, so the palm and fingers need enough mechanical protection.
- Size: gloves come in sizes — count the team members' palm sizes before buying. Gloves too large slip off easily; gloves too small restrict blood flow and make fingers go numb.
- Reflective marking: the back of the hand should carry a reflective strip, so team members can see each other's positions in smoke.
Fire Boots: Puncture, Impact, Water, Insulation
Firefighter fire protection boots follow GA 6-2004 and protect a firefighter's feet and lower legs. A boot must have waterproofing, puncture resistance, impact resistance, chemical resistance and electrical insulation all at once — none may be missing.
Focus on these points when choosing:
- Puncture resistance: the sole has a puncture-resistant layer, so stepping on a nail or broken glass does not pierce through. Take the puncture-resistance figures from the test report.
- Impact resistance: the toe has an impact-resistant inner cap that protects the toes when a heavy object falls. Check whether the internal clearance height after impact meets the standard.
- Waterproofing: the join between the upper and the sole is sealed tight, so firefighting water does not seep in. The shaft must be tall enough — generally a high-top design that protects the calf.
- Electrical insulation: a fire scene may have live equipment, so the boots must insulate electrically — take the breakdown voltage and leakage current figures from the test report.
- Heat insulation: the sole must insulate well against heat, so feet do not burn when standing on hot ground.
- Anti-slip: the sole tread must grip on wet, slippery ground and stairs.
Size boots by each team member's actual foot length. A shaft too tight restricts blood flow; one too loose wobbles when walking.
Acceptance: Certificates, Report, Try-On
Acceptance has three steps:
- Step 1, check the documents. The supplier should provide a voluntary product certification certificate, a type test report and a product certificate. The model, manufacturer and standard number on the certificate and report must match the physical product, and the report must be within its validity period. Test reports for firefighter personal protective equipment are generally issued by the National Fire Equipment Quality Supervision and Inspection Centre.
- Step 2, check the appearance. For gloves, check that the stitching is firm, all four layers are present and there is no damage; for boots, check the upper for cracks, that the sole and upper join tightly, and that the zip or buckle runs smoothly. Each product should carry a clear permanent mark showing the model, size, manufacturer, production date and executive standard.
- Step 3, try them on. Let team members actually wear them: wearing gloves, grip a nozzle, turn a valve and fasten a button; wearing boots, walk stairs and squat, confirming the size fits and movement is not restricted. The joints where gloves meet the suit sleeves, and boots meet the suit trouser legs, must overlap each other — no skin may show.
For building a mini fire station, see How to Build a Mini Fire Station: Equipment Checklist.
Frequently Asked Questions
Can ordinary labour gloves replace fire gloves?
No. Ordinary labour gloves have no heat-insulating layer or flame-retardant outer layer, and will melt and stick to the skin at high temperature. Fire gloves follow GA 7-2004 and their four-layer structure must be complete.
What is the difference between fire boots and ordinary rain boots?
Rain boots only keep water out. Fire boots must also resist puncture and impact, insulate electrically and insulate against heat, following GA 6-2004. A rain boot offers no protection at all against nails or falling heavy objects in a fire.
How often should gloves and boots be replaced?
There is no uniform fixed service life — judge by actual condition. Replace gloves when they are damaged, the heat-insulating layer has thinned or the waterproof layer has failed, and boots when they crack, the sole is badly worn or the puncture-resistant layer is exposed. Check after every use and do a full check once a year.
Do gloves and boots need to be sized before buying?
Yes. Gloves are sized by palm size and boots by foot length. Count the team members' sizes before buying and match by size — do not buy a single average size for everyone.