Category: Firefighting Equipment

Fire Drill Equipment: What to Prepare for Each Stage

The purpose of a fire drill is to test the plan and train people — not to take a few photos for the record. If the equipment is not ready, extinguishers will not open, hoses will not connect and megaphones will be dead, and the drill achieves little. This guide lists the equipment by drill stage.

Drill Frequency First: Key Units Every Six Months

Drill frequency has clear requirements: under Article 14 of the Provisions on Social Fire Safety Education and Training (Ministry of Public Security Order No. 109), fire-safety key units must organise a firefighting and emergency evacuation drill at least once every six months, and other units at least once a year. Schools must organise at least one emergency evacuation drill for students each school year, and fire-safety key areas within a school (student dormitories, canteens, laboratories and similar) must drill at least once every six months.

Before a drill, draw up a drill plan covering the purpose, time, place, participants, simulated fire, evacuation routes and division of duties. During the drill, set up clear signs and inform people in the drill area in advance, to avoid panic and accidents. After the drill, summarise promptly and revise the plan.

Extinguishing Equipment: Extinguishers, Hoses and Nozzles

Extinguishing is the core of the drill. The equipment list is:

  • Fire extinguishers: prepare enough hand-held extinguishers for every participant to practise at least once. Use extinguishers near their service date that need refilling, and send them for refilling after the drill — do not consume brand-new extinguishers on a drill. Before the drill, check that every extinguisher's pressure gauge needle is in the green zone and that the safety pin and nozzle are intact.
  • Fire hoses and nozzles: prepare hoses, nozzles and couplings, and practise the full process of laying out the hose, connecting the couplings and discharging water. Hoses follow GB 6246-2011, commonly 65 mm bore and 20 m or 25 m long. Before the drill, check hoses for damage and coupling seals for intactness.
  • Fire blankets: when practising oil-pan fire extinguishing, prepare a fire blanket and demonstrate covering to smother the fire. The blanket must fully cover the burning object, and must not be lifted immediately after the fire is out.

Evacuation Equipment: Respirators, Indicator Lights and Torches

Evacuation tests whether people can withdraw safely through thick smoke. The equipment list is:

  • Filtering self-rescue respirators: prepare enough for evacuation guides and participants to practise wearing. Respirators follow GB 21976.7-2012; the TZL30 model has a rated protection time of 30 minutes. A respirator is single-use — once opened, the filter canister starts consuming on contact with air, so prepare separate respirators for the drill and do not touch the unopened emergency stock. An expired respirator that looks intact can be used for wearing practice, since practising wearing does not consume filter performance.
  • Emergency lighting and evacuation signs: simulate a power cut during the drill to check that emergency lights and evacuation indicator lights start normally and are bright enough. Lights follow GB 17945-2024, and the emergency duration follows GB 51309-2018. Check battery condition before the drill and recharge afterwards.
  • Emergency torches: each evacuation guide carries one torch to guide the evacuation direction. Charge or replace batteries in advance — a torch with no power during the drill is the same as no preparation.

Command and First-Aid Equipment: Megaphones, First Aid Kits and Cordon Tape

Command needs megaphones and walkie-talkies: the chief commander issues drill orders by megaphone, and each group communicates by walkie-talkie. Charge megaphones in advance and test the volume; for large sites and many people, prepare amplification equipment.

First aid needs first aid kits and stretchers: when the drill simulates injuries, the first-aid group treats the injured with the kit and moves them on a stretcher. The kit should contain bandages, disinfectants, plasters and other basic items; check before the drill that items are complete and within their expiry dates.

Cordon tape and signboards: cordon off the drill area, and put signboards at the assembly point to guide people to the designated place for roll call. Choose an open, safe assembly point away from the simulated fire. Record evacuation times and problems found during the drill — the drill summary must rest on records, not impressions. For the full equipment list of a unit's own fire station, see how to build a mini fire station and the company fire equipment checklist.

Handling Equipment After the Drill

After the drill, handling the equipment matters just as much:

  • Used extinguishers are sent together for repair and refilling, then returned to place once refilled.
  • Used hoses are washed and dried before storage, and checked for damage.
  • Respirators opened and used are treated as single-use products and no longer count as emergency stock.
  • Torches and megaphones are recharged and returned to place; first aid kits are topped up with the items consumed.

Problems found in the drill go on a rectification list: top up extinguishers where numbers are short, replace damaged hose couplings, replace ageing emergency-light batteries — and complete the rectification within a deadline. A drill is not the goal; finding and fixing problems is.

Frequently Asked Questions

Can expired fire extinguishers be used for drill practice?

For hands-on practice you can use extinguishers near their service date that need refilling — but not extinguishers that have already been scrapped. A scrapped cylinder may be unsafe, and using one in a drill carries a risk.

Once a self-rescue respirator is opened for a drill, can it go back into emergency stock?

No. A filtering self-rescue respirator is a single-use product — once opened, the filter canister starts consuming on contact with air. Prepare separate respirators for drills, and do not touch the unopened emergency stock.

Must a drill be announced to everyone in advance?

Yes. During a drill, set up clear signs and inform people in the drill area in advance, to avoid panic and accidents. A surprise drill must also be safe and controllable, and must not frighten people who do not know about it.

How often should drills be held?

Fire-safety key units at least once every six months, other units at least once a year. Schools must organise at least one emergency evacuation drill for students each school year. Units may increase the frequency to suit their own situation.

WhatsApp 18300232331 Get a Free Quote