Category: Firefighting Equipment

How to Choose a Fire Hose: Size, Length & Material

A fire hose model looks like a string of code, but every number has a clear meaning. The three most common buying mistakes are a bore that does not match the hydrant, a working pressure below the system pressure, and a lining material that does not last. Read the model, the material and the acceptance checks, and the choice is straightforward.

Know the Standard First: the Current Edition Is GB 6246-2011

The current national standard for fire hoses is GB 6246-2011, Fire Hose. A fire hose is a fire product, so when buying, check the fire product certification certificate — the model and manufacturer on the certificate must match the physical product.

Note that GB 6246 is under revision and a draft for public comment has already been published; the model system will change, adding hose classifications and a new model format. Until the new edition is officially published and takes effect, purchase acceptance still follows GB 6246-2011 — write the executive standard's version number in the contract to avoid disputes when the old and new standards change over.

How to Read the Model: Three Numbers in 13-65-20

A common fire hose model is made of three groups of numbers. Taking 13-65-20 as an example: 13 stands for a design working pressure of 1.3 MPa — one tenth of the number; 65 stands for a nominal inner diameter of 65 mm; and 20 stands for a length of 20 m. Once you can read these three numbers, most of the selection is done.

Bore: 65 mm is the most common specification, matching the indoor hydrant SN65 and the DN65 coupling, commonly called 2.5 inches. 80 mm, 50 mm, 40 mm and 25 mm also exist, matching different hydrants and hose reels. The bore must match the hydrant outlet and the nozzle coupling — a 65 hydrant takes a 65 hose; mixing them will not connect.

Working pressure: common grades are 0.8 MPa, 1.0 MPa, 1.3 MPa, 1.6 MPa, 2.0 MPa and others, and the number in the model is ten times the pressure value. Choose a working pressure above the system's actual working pressure, leaving a safety margin. High-rise buildings and fire-engine supply, where pressure is high, need models of 1.6 MPa and above.

Length: 20 m and 25 m are common; hydrant cabinets generally take 20 m, and fire brigades use 30 m and 40 m. Set the length by the protection distance and the actual site need — too short and it cannot reach the fire, too long and it is awkward to coil and adds resistance.

How to Choose the Material: the Lining Decides Durability

A fire hose is made of a woven layer and a lining. The woven layer commonly uses polyester filament or polypropylene filament — polyester is strong and wear-resistant, polypropylene is light and corrosion-resistant. The lining is mainly one of three materials: polyurethane, rubber or polyvinyl chloride.

A polyurethane lining is the current mainstream: light in weight, soft and easy to coil, ageing-resistant and low in resistance, suited to hydrant cabinets and everyday stock. A rubber lining is wear-resistant, pressure-resistant and cold-resistant, suited to heavy-duty fire-brigade use, but heavy and more expensive. A polyvinyl chloride lining is cheap, but its cold resistance and ageing resistance are poor — it easily stiffens and cracks in low temperatures.

When buying, look at the key figures in the test report: burst pressure, adhesion strength, elongation, expansion rate and mass per unit length. These figures show the hose's real quality — appearance and feel alone are not a reliable guide.

Acceptance: Check the Marking, the Couplings and the Weave

Each hose should be clearly printed near its end in indelible ink with the product name, specification and model, manufacturer name, registered trademark and production date. Treat unclear or incomplete marking with caution.

The couplings are the focus: both ends of the hose should have internal-snap couplings, the bindings between coupling and hose should be sound, and the binding should be protected by a sleeve. Couplings are generally aluminium alloy — check for cracks or deformation and that the sealing rings are intact. The coupling size must match the hydrant and nozzle — a 65 hose takes 65 couplings.

The woven layer should be woven evenly with a neat surface, free of double-warp skips, double-warp breaks, weft skips and scratches. The lining should be of even thickness, with a smooth, flat surface and no folds. When sampling, run water under pressure and check for leakage or bulging.

Use and Storage: Dry Before Rolling Up Again

After use, a fire hose should be cleaned and dried; a damp hose must not be rolled up and stored, or it easily goes mouldy and the lining sticks together. When drying, avoid direct sunlight — ultraviolet light speeds ageing of the woven layer and lining.

When storing, coil the hose neatly and keep it in a hydrant cabinet or a dry, ventilated store room, away from heavy pressure and sharp objects. Check regularly for mould, sticking or coupling rust, and replace a problem hose promptly. A fire hose has no uniform scrapping age — judge by actual condition, and scrap at once any hose that leaks or whose burst pressure fails to meet the standard. For hose care, see How to Maintain Fire Hoses: Drying & Storage; for how to work out how many extinguishers a place needs, see How to Configure Fire Extinguishers: Place, Quantity and Inspection, and for home extinguisher choice, see How to Choose a Home Fire Extinguisher.

Frequently Asked Questions

What is the difference between 13-65-20 and 10-65-20?

The difference is working pressure. 13 means 1.3 MPa and 10 means 1.0 MPa; both have a 65 mm bore and a 20 m length. Places with high system pressure must choose 13 or above — do not buy a low-pressure hose just because it is cheaper.

Can a hose be lengthened by joining?

Yes — two hoses join through their couplings to make a longer run. But more couplings mean more leak points and greater head loss. If one hose reaches, do not join two; fire brigades join several hoses in series only for long-distance water supply.

Which is better, a polyurethane lining or a rubber lining?

Neither is absolutely better — it depends on use. Choose polyurethane for everyday hydrant-cabinet stock, as it is light and easy to coil; choose rubber for heavy-duty fire-brigade use in harsh environments, as it is wear- and pressure-resistant. Choose by how hard it will be used, not by price alone.

Should a newly bought hose be pressure-tested?

For bulk purchases, sample pressure testing is recommended. Run a water pressure test as the standard requires and check for leakage, bulging or coupling separation. Appearance alone is not enough at acceptance — only a pressure test reveals internal quality problems.