School Fire Equipment Guide: Classrooms to Laboratories

A school is one of the most crowded places there is, students are weak at saving themselves, and dormitories, canteens and laboratories each carry their own fire risks. School fire equipment must achieve this: every key area has equipment, and every student knows how to use it. This guide explains school fire equipment by place.

Management Requirements First: Set Drill and Inspection Frequencies

School fire safety management rests on the Fire Protection Law of the People's Republic of China, the Provisions on Fire Safety Management of State Organs, Organizations, Enterprises and Institutions, the Provisions on Fire Safety Management of Higher Education Institutions, and the Provisions on Social Fire Safety Education and Training.

Drill frequency has clear requirements: under the Provisions on Social Fire Safety Education and Training, at least one emergency evacuation drill for students must be organised each school year; fire-safety key areas within a school (student dormitories, canteens, laboratories and similar) must organise a fire drill at least once every six months. Higher education institutions must give each intake of new students at least 4 hours of fire safety education and training.

Extinguisher inspection follows GB 50444-2008, Code for Acceptance and Inspection of Fire Extinguisher Installation in Buildings: generally checked once a month, and in crowded places such as student dormitories and canteens, once every half month. For the full equipment list of a unit's own fire station, see how to build a mini fire station and fire drill equipment.

Teaching Buildings: Corridors and Stairwells Are the Focus

A teaching building is a light-to-medium hazard Class A fire place, with ABC dry powder extinguishers as the main type, configured under GB 50140-2005, Code for Design of Extinguisher Installation in Buildings: at least 2 extinguishers per calculation unit, and no more than 5 per setting point.

Setting positions: evacuation corridors and stairwell entrances on each floor are the priority points. The top of a hand-held extinguisher must be no more than 1.50 m above the floor, and the bottom no less than 0.08 m above the floor; extinguishers should sit in extinguisher cabinets or on hooks or brackets, and extinguisher cabinets must not be locked. More can be added at classroom doors and corridor corners for easy access.

Evacuation signs and emergency lighting matter just as much: safety exit signs sit above exit doors, direction signs sit in evacuation corridors, and emergency lights keep stairwells and corridors bright enough after a power cut. Lights follow GB 17945-2024, and the emergency duration follows GB 51309-2018 — generally not less than 0.5 hours for ordinary buildings.

Student Dormitories: A Key Area with Strict Electrical Rules

Student dormitories are a key area of school fire safety, with fires mostly caused by illegal use of high-power appliances, privately pulled wiring, and smoking in dormitories. Dormitory extinguishers are configured to the medium hazard level, with at least 2 ABC dry powder extinguishers per floor, at stairwell entrances and the middle of corridors as priority points.

Each dormitory floor must have hydrant equipment: fire hoses, nozzles and couplings complete, checked once a month. Dormitory buildings should have emergency lighting and evacuation signs, so students can see the evacuation route after a power cut.

Dormitory management must go with the equipment: electric stoves, electric blankets and other high-power appliances are forbidden, and private wiring is forbidden; dormitory buildings should set up a central charging area, and electric bike batteries must not be brought into buildings or dormitories to charge; each floor should have a designated person responsible for daily checks of the fire equipment.

Canteens and Laboratories: Special Places Need Special Equipment

A canteen kitchen is a Class F fire place — an oil-pan fire must not be put out with water. Each kitchen work area should have a fire blanket and an ABC dry powder extinguisher, with the fire blanket hung where it is easy to reach and see; near gas stoves, steamers and similar equipment, fit carbon dioxide extinguishers or dry powder extinguishers. Clean range-hood ducts regularly — built-up grease is a common cause of kitchen fires.

Laboratory configuration depends on the experiments: a chemistry laboratory with flammable reagents and gas cylinders is a Class B and C fire place, with ABC dry powder extinguishers and carbon dioxide extinguishers; a laboratory with alkali metal (potassium, sodium) experiments has Class D dry powder extinguishers and must not use water-type extinguishers; a laboratory with much electrical equipment has carbon dioxide extinguishers. Laboratory doors should carry hazardous-goods signs, and reagent cabinets and gas cylinder rooms are key inspection points. Libraries and archives have carbon dioxide extinguishers or clean-agent extinguishers, to avoid dry powder contaminating books and files.

Once Bought, Students Must Know How to Use Them

The last link in school fire equipment is training. Equipment nobody knows how to use is the same as no equipment at all. A school should achieve:

  • At least one whole-school emergency evacuation drill each school year, so every student walks the evacuation route once.
  • At least 4 hours of fire safety education for new students on enrolment, covering how to use extinguishers, hydrants and self-rescue respirators.
  • A fire safety officer in every class and every dormitory, who can report a fire, use an extinguisher and organise evacuation.
  • Operating instructions for extinguishers and hydrants posted beside the equipment, with pictures and text, so a student understands at a glance.

For the company-side counterpart, see the company fire equipment checklist.

Frequently Asked Questions

How often should school fire extinguishers be checked?

Generally once a month; in crowded places such as student dormitories and canteens, once every half month. The basis is GB 50444-2008, Code for Acceptance and Inspection of Fire Extinguisher Installation in Buildings.

Can student dormitories use water-based fire extinguishers?

Dormitories mainly use ABC dry powder extinguishers. Dormitories carry an electrical fire risk, and water-based extinguishers are not suited to live electrical fires — dry powder extinguishers are more generally applicable.

How many fire drills must a school organise each school year?

Under the Provisions on Social Fire Safety Education and Training, at least one emergency evacuation drill for students each school year; fire-safety key areas within a school must drill at least once every six months.

What extinguishers should a laboratory have?

It depends on the experiments: a general chemistry laboratory has ABC dry powder extinguishers and carbon dioxide extinguishers; a laboratory with alkali metal (potassium, sodium) experiments has Class D dry powder extinguishers and must not use water-type extinguishers; a laboratory with much electrical equipment has carbon dioxide extinguishers. The exact choice follows the laboratory safety assessment.