Category: Fire Equipment

Hospital Fire Equipment: How to Set It Up

Setting up fire equipment in a hospital differs from an ordinary workplace: many people, including patients who move slowly, need longer to evacuate, so extinguishers, emergency lighting, exit signs, hydrants and hoses must be set up by floor and zone. This guide works through the five kinds of equipment by hospital floor and zone.

Extinguishers: Choose by Area, Count by Calculation Unit

Extinguishers are the hospital's first line of fire defence — what to use and how many depends on the area:

  • General areas take ABC dry powder: universal and cheap, for wards, corridors and offices. Machine rooms, power distribution rooms and precision instrument rooms take carbon dioxide, which leaves no residue — see How to Set Up Fire Extinguishers: Areas, Quantities & Inspection.
  • Quantities follow GB 50140-2005: at least two extinguishers per calculation unit, with the exact count worked out by floor area and fire risk level. For the exact count per ward and floor, please call 18300232331 to confirm.
  • Inspection and scrapping: a dry powder extinguisher is scrapped after 10 years, so one bought after three years in storage has only seven years of use left. Ask the supplier for recently produced goods when buying in bulk — see Fire Extinguisher Inspection & Scrapping Rules.
  • Extinguisher selection for special areas such as oxygen cylinder stores and operating theatres is not covered on this site — please call 18300232331 to confirm before setting those up.

Emergency Lighting and Exit Signs: Set Up by Floor, Never Blocked

Evacuation is slow in hospitals, so emergency lighting and exit signs are a lifeline — set them up fully, keep them working, and never block them:

Hydrants, Hoses and Nozzles: Set Up by Floor, Tested Regularly

Frequently Asked Questions

How are hospital extinguishers set up — are wards and machine rooms the same?

No: general areas take ABC dry powder, which is universal and cheap, while machine rooms, power distribution rooms and precision instrument rooms take carbon dioxide, which leaves no residue. Quantities follow GB 50140-2005, with at least two extinguishers per calculation unit. For the exact count per ward and floor, please call 18300232331 to confirm.

What is special about emergency lighting and exit signs in hospitals?

Hospitals hold many people, including patients who move slowly, so evacuation takes longer than in ordinary buildings — emergency lighting and exit signs must stay in working order and never be blocked. For twin-head and sign lights, see this site's fire emergency light guide; for single- and double-sided signs, see the exit sign guide.

How often should hospital fire equipment be checked?

Follow this site's fire equipment inspection checklist: monthly and quarterly checks together, with extinguishers checked by pressure gauge and expiry date, and hydrants checked for hoses, nozzles and couplings in good order. Fix or replace problems as soon as they are found — do not wait for a fire inspection to deal with them.

What certificates must be checked when buying hospital fire equipment?

Fire products must hold a 3C certificate, whose number can be checked on the issuing body's website — extinguishers, hoses, nozzles and emergency lights all need checking. At acceptance, follow the three steps — match the order, the papers and the goods — and the model, standard number and test results on the report must match the goods.

WhatsApp 18300232331 Get a Free Quote
Chat Get a Quote